RS101 Pneumatic Shielding Box
Applications
| The RS-101 Pneumatic Shielding Box provides an efficient therefor isolated test environment for the manufacturing of notebook and PDA assemblies. |
|
| Features |
| Pneumatic control for manual for semi-automatic operation |
 |
High RF shielding, > 80 dB |
 |
EMI filters on all data connector |
 |
Safety protective switch |
| Lid Operation |
 |
Long Life. Typically 100,000 open/close cycle. |
 |
Ability to control lid opening and closing speed. |
 |
Lid opens when the compressed air is connected or power is turned on. |
| Specifications |
| Shielding effectiveness |
> 80dB to 2GHz including connectors. Typically > 70dB to 2.4GHz, > 50dB to 5 ~ 6 GHz. |
| Thorefore connector |
Type N, SMA. |
| Data Connector |
Two 9 pin and one 25 pin D-Type, filtered. |
| DC connection |
RCA connector |
| Line Voltage |
110 volt AC, 60Hz, 50 watt. |
| Compressed air requirement |
Minimum 4 bar, maximun 7 bar |
| Working Space |
360(W)×569(D)×540(H)mm, close state, 950(H)mm , open state. |
| Box Color |
Computer while |
| Weight without handler and fixture |
81.6Kg |
|